|
|
| ||||||||||||||||
|
|
|||||||||||||||||
|
ellipsometers
|
|||||||||||||||||
|
| |||||||||||||||||
|
overview Ellipsometry is superior to alternate methods of thin film measurement such as reflectometry because two parameters (DELTA and PSI) instead of one (intensity) are independently determined in any single measurement. This fact permits the film refractive index to be measured in addition to the film thickness. Two independent parameters also place tighter constraints on models representing more complicated films. In addition, ellipsometric measurements are insensitive to intensity fluctuations of the source, temperature drifts of electronic components, and macroscopic roughness which can be a serious problem in reflectometry but not in ellipsometry, for which absolute intensity measurements are not required. Transparent films from under one angstrom up to several microns and absorbing films less than 500 angstroms thick can be measured ellipsometrically. The surface upon which the film is measured can be a semiconductor, dielectric or metal. The film can be transparent or absorbing in a medium of transparent solid, liquid, gas or vacuum. The measuring polarized light can range from the ultra violet to the Infrared. Gaertner Scientific has helped pioneer this exciting field since the late 30's when we constructed our first polarizing spectrometer. We are proud of our past involvement and look forward to supplying our customers with instruments of the finest quality.
applications of ellipsometry
brief theory At the end of the 1800's, Paul Drude stated the relationship between thickness of the film and the optical constants of the surface (or substrate) upon which the film is deposited. This relationship is mathematically stated as the fundamental equation of ellipsometry:
The ellipsometer is used to measure PSI and DELTA, and thus with the known values of PSI, and DELTA the film thickness and index can be calculated. Since the equation contains complex quantities, its solution is done by computer. While a number of different ellipsometry methods exist for obtaining PSI and DELTA the most common are the nulling, rotating analyzer, and exclusive to Gaertner the StokesMeter™ method. The oldest measurement method is manual nulling which requires rotating the polarizer and analyzer circles until the reflected beam from the sample is extinguished. When extinction is achieved (takes a few minutes), the polarizer and analyzer circles are read. These readings are then converted into film thickness and film refractive index by using tables, graphs, or personal computers. Our model L117F an example of a manual nulling type ellipsometer. Measurement by automatic ellipsometers was introduced with the advent of the personal computer. Typically a rotating analyzer encodes the reflected beam intensity in less than one second, then a A/D converter digitizes the intensity and sends the data to a computer where the data is modeled for film thickness and film refractive index. Our model L2W16ir633.1500 is an example of a rotating analyzer ellipsometer. Newer methods such as the StokesMeter™ polarimeter measure by reflecting the measuring light beam from 4 stationary detectors. The measuring laser light beam can be described by the normalized stokes parameters [1,S1,S2,S3] which in turn yield PSI and DELTA. Our model L115S is an example of a Stokes Ellipsometer. For a more thorough theoretical treatment of ellipsometry, the reader is referred to the publications page. |
| company info | email@gaertnerscientific.com |
© 2006-2010 gaertner scientific corporation |
|