basic modular microscope M101B
components diagram

The M101B modular microscope includes the M242 10X eyepiece,
M250-242 eyepiece adapter, and the M222 objective as standard components.
These components can be substituted for the components listed below or
from others shown on our website.
eyepiece adapters
Eyepieces of different power have different lengths so the appropriate adapter must be used with each in order to permit interchange
of eyepieces without altering the optical tube length of the microscope.
Each standard adapter contains 90º cross hairs, or upon request a 60º cross
hairs or a single filar cross hair can be substituted. Special
types of reticles can also be supplied. Adapters are
not included with eyepieces, but can be ordered individually if desired.
| |
Adapter |
Use with Eyepiece |
|
M250-242 |
M242 - 10x |
|
M250-240 |
M240 - 14x |
|
M250-239 |
M239 - 20x |
|
M250S |
M2001EYS -
10x Wide field |
eyepiece
and objective combinations for the M101B microscope
The M101B has a 168mm optical tube length. The M193 Erecting
Prism adds
26mm to the optical tube length, thereby increasing the magnification and
decreasing the field of view and working distance.
|
Eyepiece |
Objective
|
EFL(mm)
|
Total
Magnification
|
Working
Distance (mm)
|
Object
Field
Diameter (mm)
|
|
Optical
Tube Length (mm) |
|
|
168 |
194 |
168 |
194 |
168 |
194 |
|
|
|
M242 |
M216 |
8 |
200x |
217x |
1.9 |
1.8 |
0.5 |
0.46 |
| M218 |
16 |
100x |
103x |
8.6 |
8.4 |
1.0 |
0.97 |
| M219 |
25 |
59x |
66x |
17 |
15 |
1.7 |
1.5 |
| M220 |
32 |
42x |
53x |
40 |
38 |
2.4 |
1.9 |
| M222 |
38 |
34x |
39x |
49 |
47 |
2.9 |
2.4 |
| M224 |
48 |
25x |
29x |
67 |
64 |
4.0 |
3.3 |
| M225 |
60 |
18x |
21x |
93 |
87 |
5.5 |
4.5 |
| M225C |
67 |
15x |
18x |
114 |
102 |
6.6 |
5.6 |
| M226 |
80 |
11x |
13x |
157 |
136 |
9.1 |
7.0 |
| M227 |
102 |
6.5x |
9x |
260 |
215 |
15.5 |
11.0 |
|
|
|
M240 |
M216 |
8 |
280x |
304x |
1.9 |
1.8 |
0.5 |
0.46 |
| M218 |
16 |
140x |
144x |
8.6 |
8.4 |
1.1 |
0.97 |
| M219 |
25 |
83x |
92x |
17 |
15 |
1.7 |
1.5 |
| M220 |
32 |
59x |
74x |
40 |
38 |
2.4 |
1.9 |
| M222 |
38 |
48x |
55x |
49 |
47 |
2.9 |
2.4 |
| M224 |
48 |
35x |
41x |
67 |
64 |
4.0 |
3.3 |
| M225 |
60 |
25x |
29x |
93 |
87 |
5.5 |
4.5 |
| M225C |
67 |
21x |
25x |
114 |
102 |
6.6 |
5.6 |
| M226 |
80 |
15x |
18x |
157 |
136 |
9.1 |
7.0 |
| M227 |
102 |
9x |
13x |
260 |
215 |
15.5 |
11.0 |
|
|
|
M239 |
M216 |
8 |
400x |
434x |
1.9 |
1.8 |
0.5 |
0.46 |
| M218 |
16 |
200x |
206x |
8.6 |
8.4 |
1.1 |
0.97 |
| M219 |
25 |
118x |
132x |
17 |
15 |
1.7 |
1.5 |
| M220 |
32 |
84x |
106x |
40 |
38 |
2.4 |
1.9 |
| M222 |
38 |
68x |
78x |
49 |
47 |
2.9 |
2.4 |
| M224 |
48 |
50x |
58x |
67 |
64 |
4.0 |
3.3 |
| M225 |
60 |
36x |
42x |
93 |
87 |
5.5 |
4.5 |
| M225C |
67 |
30x |
36x |
114 |
102 |
6.6 |
5.6 |
| M226 |
80 |
22x |
26x |
157 |
136 |
9.1 |
7.0 |
| M227 |
102 |
13x |
18x |
260 |
215 |
15.5 |
11.0 |
|
|
|
M2001EYS |
M216 |
8 |
200x |
217x |
1.9 |
1.8 |
1.0 |
0.9 |
| M218 |
16 |
100x |
103x |
8.6 |
8.4 |
2.2 |
1.9 |
| M219 |
25 |
59x |
66x |
20 |
15 |
3.4 |
3.0 |
| M220 |
32 |
42x |
53x |
39 |
38 |
4.8 |
3.8 |
| M222 |
38 |
34x |
39x |
49 |
47 |
5.8 |
4.8 |
| M224 |
48 |
25x |
29x |
67 |
64 |
8.0 |
6.6 |
| M225 |
60 |
18x |
21x |
93 |
87 |
11 |
9.0 |
| M225C |
67 |
15x |
18x |
114 |
102 |
13 |
11 |
| M226 |
80 |
11x |
13x |
157 |
136 |
18 |
14 |
| M227 |
102 |
6x |
9X |
260 |
215 |
31 |
22 |
back
to microscopes
|